Tabriz University of Medical Sciences About    Newsletter    Contact Us    Create Account    Log in  

ISSN: 1735-403X      eISSN: 2383-2886  
Services
Export citation
EndNote
Reference Manager
BibTeX
Medlars
Refworks
Mendeley

Cite by
Google Scholar



Article History
Submitted: 07 Oct 2017
Revised: 16 Dec 2017
Accepted: 30 Dec 2017
First published online: 20 Jun 2018

Article Access Statistics
Abstract Page Views: 48
PDF Downloads: 189
Full Text Views: 0

Pharm Sci. 2018;24(2):131-140 doi: 10.15171/PS.2018.20

A Sensitive High-Performance Thin Layer Chromatography Method for Simultaneous Determination of Salbutamol Sulphate and Beclomethasone Dipropionate from Inhalation Product

Research Article

Nizam Patel 1, Vijaykumar Kunvarji Parmar 1 *

1 Ramanbhai Patel College of Pharmacy, Charotar University of Science and Technology, CHARUSAT Campus, Changa – 388421, Ta. Petlad, Dist. Anand, Gujarat, India.



Abstract
Background: A sensitive high-performance thin layer chromatographic (HPTLC) method was developed for simultaneous determination of beclomethasone dipropionate and salbutamol sulphate from inhalation product. Methods: Chromatographic separation was achieved on aluminium plates pre-coated with silica gel G60 F254 as the stationary phase and methanol:ethyl acetate:toluene:ammonia (3:1:3:0.15) as the mobile phase. The densitometric evaluation was carried out at 232 nm. The developed method was validated as per the ICH Q2 (R1) guidelines. Robustness of the proposed method was assessed using experimental design approach, and results were analyzed graphically. The results of sample analysis by proposed HPTLC method and reported HPLC method were statistically compared. Results: The Rf value of salbutamol sulphate and beclomethasone dipropionate was found to be 0.38±0.02 and 0.72±0.02, correspondingly. The response in terms of peak area was linear over the concentration range of 100-500 ng/spot and 200-1000 ng/spot for beclomethasone dipropionate and salbutamol sulphate, individually, with the regression coefficient values greater than 0.99 for both the drugs. The limit of detection and limit of quantification for beclomethasone dipropionate were found to be 27 ng/spot and 84 ng/spot, respectively and for salbutamol sulphate were 40 ng/spot and 112 ng/spot, respectively. The proposed method was found to be statistically insignificant when compared to the reported method. Conclusion: The proposed method is robust, sensitive, accurate and precise. The method can be applied for the simultaneous estimation of beclomethasone dipropionate and salbutamol sulphate from inhalation product.





Comments
First name  
Last name  
Email address  
Comments  
Security code



This Article
PDF

Google Scholar
Articles by Patel N
Articles by Parmar VK

PubMed
Articles by Patel N
Articles by Parmar VK



Share this article!
© 2016 Tabriz University of Medical Sciences; unless otherwise stated
Press Manuscript Online. Powered by MAADRAYAN