Adv Pharm Bull. 2016;6(2):257-260 doi: 10.15171/apb.2016.035

The Effect of Spacer Morphology on the Aerosolization Performance of Metered-Dose Inhalers

Short Communication

Sepideh Momeni 1,2, Ali Nokhodchi 3, Saeed Ghanbarzadeh 4,5, Hamed Hamishehkar 5 *

1 Biotechnology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
2 School of Pharmacy, International Branch-Aras, Tabriz University of Medical Science, Tabriz, Iran.
3 School of Life Sciences, University of Sussex, Falmer, Brighton BN1 9QG, United Kingdom.
4 Zanjan Pharmaceutical Nanotechnology Research Center, and Department of Pharmaceutics, Faculty of Pharmacy, Zanjan University of Medical Sciences, Zanjan, Iran.
5 Drug Applied Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.



Abstract

Purpose: Respiratory drug delivery has been attracted great interest for the past decades, because of the high incidence of pulmonary diseases. However, despite its invaluable benefits, there are some major drawbacks in respiratory drug delivery, mainly due to the relatively high drug deposition in undesirable regions. One way to improve the efficiency of respiratory drug delivery through metered-dose inhalers (MDI) is placing a respiratory spacer between the inhaler exit and the mouth. The aim of this study was to assess the effect of type and shape of spacer on the aerosolization performance of MDIs.

Methods: A commercial Beclomethasone Dipropionate (BDP) MDI alone or equipped with two different spacer devices (roller and pear type) widely distributed in the world pharmaceutical market was used. The effect of spacers was evaluated by calculating aerosolization indexes such as fine particle fraction (FPF), mass median aerodynamic diameters (MMAD) and geometric standard deviation (GSD) using the next generation impactor.

Results: Although one of the spacers resulted in superior outcomes than the other one, but it was not statistically significant.

Conclusion: The results confirmed that the type and shape of spacer did not substantially influence the aerosolization performance of MDIs.







Comments
First name  
Last name  
Email address  
Comments  
Security code



This Article
PDF

Google Scholar
Articles by Momeni S
Articles by Nokhodchi A
Articles by Ghanbarzadeh S
Articles by Hamishehkar H

PubMed
Articles by Momeni S
Articles by Nokhodchi A
Articles by Ghanbarzadeh S
Articles by Hamishehkar H



Share this article!

Press Manuscript Online. Powered by MAADRAYAN